• Users Online: 1118
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 19  |  Issue : 2  |  Page : 105-108

An in vitro evaluation of bacterial penetration through different kinds of surgical drapes


1 Department of Microbiology, VSS Institute of Medical Sciences and Research, Sambalpur, Odisha, India
2 Department of Anaesthesiology, VSS Institute of Medical Sciences and Research, Sambalpur, Odisha, India

Correspondence Address:
Dr. Susanta Kumar Sahu
Department of Microbiology, VSS Institute of Medical Sciences and Research, Burla, Sambalpur - 768 017, Odisha
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jacm.jacm_75_16

Rights and Permissions

PURPOSE: Surgical site infection is a major cause of increased post-operative morbidity. The surgical drape functions as a barrier between the surgical field and the potential sources of microorganisms in the environment and operating room personnel. The extent to which the materials act as barrier depends on the closeness of the weave and water-resistant properties of the fabric. This is an in vitro study to evaluate the ability of different types of surgical drapes to prevent bacterial strike through. MATERIALS AND METHODS: Four types of fabrics used as surgical drapes were tested for their ability to prevent strike through when exposed to different bacteria for varying spans of time. We tested the drapes with Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa. RESULTS: Drapes made of cotton (CC) or polyester-cotton (PC) textile exhibited least resistance to bacterial penetration. Disposable woven continuous filament polyester fabrics showed better resisting powers. The disposable non-woven polythene fabrics were found to resist bacterial penetration most effectively. The penetration through the woven fabrics was found to be dose- and time-dependent. CONCLUSION: The practice of using reusable textile clothes as surgical drapes should be discontinued and be replaced by non-woven seamless disposable fabric. Surgical drapes should be tested for their penetrability before introducing in operation theatre.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4107    
    Printed227    
    Emailed0    
    PDF Downloaded18    
    Comments [Add]    
    Cited by others 1    

Recommend this journal